Here you can find an overview for the standard spectrometers (UV-VIS-IR) and options Iberoptics offers:
Range (nm) | Res. (nm, 25um slit) | |
STN-BW-VIS | 350-1150 | 1.00 |
STN-BW-VIS2 | 380-780 | 0.50 |
STN-BW-NIR | 500-1150 | 1.00 |
STN-BW-NIR2 | 600-1000 | 0.50 |
STN-BW-NIR2b | 785-1150 | 0.50 |
STN-BW-NIR3 | 550-840 | 0.35 |
STN-BW-NIR3b | 690-935 | 0.35 |
STN-BW-NIR4 | 500-700 | 0.25 |
STN-BW-NIR4b | 600-800 | 0.25 |
STN-BW-UV | 200-600 | 0.50 |
STN-BW-UV2 | 200-400 | 0.25 |
STN-BW-UV3 | 220-350 | 0.16 |
STN-BW-UVIS | 300-1100 | 1.00 |
STN-BW-UVN | 250-1100 | 1.00 |
STN-BW-UVNb | 200-1050 | 1.00 |
Options BlueWave | ||
STN-DLENS | cylindrical lens on detector window for 3x signal gain | |
STN-TEC | TEC: allows long int. time (<3s); improves SNR 66% | |
STN-Jack 1-IN Trigger | TTL Input to Enable Spectrometer Scan | |
STN-ZAP2 | Wireless cpu with Wifi access to spectrometer | |
STN-BLK-C | 190-850 | 0.85 |
STN-BLK-CXR | 280-900 | 0.85 |
STN-BLK-C-SR | 200-1080 | 1.30 |
STN-BLK-CXR-SR | 220-1100 | 1.30 |
STN-BLK-HR-UV | 200-600 | 0.4 |
STN-BLK-HR-VIS | 380-750 | 0.4 |
Options BlackComet | ||
STN-Black-Comet-TEC | TEC: allows long int. time (<3s); improves SNR >50% | |
STN-Jack 1-IN Trigger | TTL Input to Enable Spectrometer Scan | |
STN-ZAP2 | Wireless cpu with Wifi access to spectrometer | |
STN-SilverNova | 200-1100 | 1.00 |
Options SilverNova | ||
STN-SilverNova-TEC-X2 | 2-stage TEC: -30ºC | |
STN-Inter-slits | Interchangeable slits upgrade | |
STN-Jack 1-IN Trigger | TTL Input to Enable Spectrometer Scan | |
STN-ZAP2 | Wireless cpu with Wifi access to spectrometer | |
STN-GW-VIS | 350-1150 | 1.00 |
STN-GW-NIR | 500-1150 | 1.00 |
STN-GW-NIR2 | 600-1000 | 0.5 |
STN-GW-NIR2b | 785-1150 | 0.5 |
STN-GW-NIR3 | 550-840 | 0.35 |
STN-GW-NIR3b | 690-935 | 0.35 |
STN-GW-NIR4 | 500-700 | 0.25 |
STN-GW-NIR4b | 600-800 | 0.25 |
STN-DS-InGaAs-512-NIR | 900-1700 | 2.5 |
STN-DS-InGaAs-512-NIRb | 1000-1700 | 2 |
STN-DS-InGaAs-512-NIR2 | 1250-1575 | 1.3 |
STN-DS-InGaAs-512-NIR2b | 1150-1475 | 1.3 |
STN-DS-InGaAs-1024-NIR | 1000-1700 | 1.25 |
STN-DS-InGaAs-512-NIR3-HR | 1530-1605 | <0.9 |
STN-DS-InGaAs-1024-NIR3-HR | 1500-1640 | <0.9 |
STN-RW-NIRX-512 | 1500-2200 | 3 |
STN-RW-NIRX-1024 | 1500-2200 | 1.4 |
STN-RW-NIRX-512-SR | 900-2300 | <13 |
STN-RW-NIRX-1024-SR | 900-2300 | <7 |
Options InGaAs spectrometers | ||
STN-Jack 1-IN Trigger | TTL Input to Enable Spectrometer Scan | |
STN-ZAP2 | Wireless cpu with Wifi access to spectrometer |
If the spectral resolution of the standard models is not enough for your application please, contact our sales team: info@iberoptics.com. We can offer non-standard models with resolution down to 0.05 nm.
Remember to check the following accessories:
- fiber optic cables
- spectroscopy accessories
- radiometry accessories and integrating spheres
- light sources