High end CW fiber lasers from the specialist Keopsys (Lumibird group) for typical applications like Scientific, LIDAR, Aerospece or Defence.
A broad range of CW fibre lasers in Thulium (2 um), Erbium (1550 nm), Ytterbium (1 um, 1064 nm), Green, Visible, UV, Raman or Broadband sources
Description of the families of CW fiber lasers
CTFL: CW Thulium-Doped Fiber Lasers
| KEO-CTFL-TERA |
Max Power | 1 - 30 W |
Wavelength, nm | 1900 - 2050 |
Platform | Benchtop, OEM |
Output | FC/APC, collimated |
Key Applications | - Medical surgery - Medical treatment - Solid state pumping - Nonlinear effect studies - Plastics material processing - Defense counter-measure |
CEFL: CW Erbium-Doped Fiber Lasers
| KEO-CEFL-KILO | KEO-CEFL-TERA |
| Single Frequency | |
Main application | Laser atomic cooling | Spectroscopy, non-linear apps |
Linewidth | 3, 5, 15, 50 KHz | < 1 nm |
Max Power | 1-15 W | 1 - 30 W |
Wavelength, nm | 1555 ±10 | 1532 ±1, 1535 ±1, 1559 ±5 |
Platform | Benchtop, OEM (up tp 2W) | Benchtop, OEM (up tp 2W) |
Output | FC/APC, E2PS, collimated | FC/APC, collimated |
Key Applications | - LIDAR - Acoustic or seismic sensing - Atom cooling - Atomic spectroscopy - Optical tweezing | - Optical component testing - Laser trapping - Medical (dermatology) - Spectroscopy - Nonlinear optics - OPO and Thulium fiber pumping |
CRFL: CW Raman Fiber Laser
| KEO-CRFL |
Main application | Distributed Raman amplification |
Linewidth | < 2nm or < 3 nm |
Max Power | 2 - 20 W |
Wavelength, nm | 1455 - 1580 |
Platform | Benchtop, OEM |
Output | FC/APC, E2PS, collimated |
Key Applications | - Distributed Raman amplification - Remote EDFA pumping - Pump splitting architecture - Fiber optic component testing |
CYFL: CW Ytterbium-Doped Fiber Lasers
| KEO-CYFL-KILO | KEO-CYFL-MEGA | KEO-CYFL-GIGA | KEO-CYFL-TERA |
| Single Frequency | Single Mode | | |
Main application | Scientific | Sensing, SHG | Helium pumping | Spectroscopy |
Linewidth | <15 kHz (G1) <20 kHz (G2) <3 kHz (G3) | 4 MHz typ, 20 MHz mx | 2 GHz max | < 2 nm |
Max Power | 1-20 W | 1-20 W | 2- 20 W | 1-20 W |
Wavelength, nm | 1064, 1083 | 1064 | 1083 | 1075 ±15 |
Platform | Benchtop | Benchtop, OEM | Benchtop | Benchtop (OEM on request) |
Output | FC/APC, E2PS, collimated | FC/APC, E2PS. collimated | FC/APC, E2PS. collimated | FC/APC, collimated |
Key Applications | - Quantum optics, like BOSE-Einstein condensate - Optical tweezer - Atomic laser interferometry - Formation of cold molecules - Nonlinear optics (SHG, OPO) - Metrology | - Sensing - Second harmonic generation (SHG) - Optical component testing | - Medical imaging - Nuclear physics - Helium pumping for medical lung imaging - Absorption spectroscopy - Wavelength conversion | - Optical component testing - Laser trapping - Spectroscopy - Atomic laser interferometry - Optical tweezing |
CVFL: CW Visible Doped Fiber Lasers
| KEO-CVFL-KILO | KEO-CVFL-MEGA | KEO-CVFL-GIGA-6xx-7xx | KEO-CVFL-GIGA-5xx |
| Single frequency | Single Long. and Transv. modes | | |
Main application | Atom cooling | Scientific | Super resolution microscopy | |
Linewidth | KHz | down to MHz | 20 GHZ | typ. 20 GHz |
Max Power | 2 W | 2 W | 3 W | |
Wavelength, nm | 530-560, 630-650, 767-790 | | 635-665, 767-790 | 520-590 |
Standard wavelength, nm | 531, 532, 767, 775, 778, 780 | 532, 767, 780 | 642, 660, 780 | 520, 532, 546, 560, 577 |
Platform | Benchtop | Benchtop | Benchtop | Benchtop |
Output | FC/APC, free-space | FC/APC, free-space | Free-space | Free-space |
Key Applications | - Atom cooling - Quantum optics - Formation of cold molecules - Entangled photon generation - Optical tweezing - Metrology | - Quantum optics, like BOSE-Einstein condensate - Optical tweezing - Atomic laser interferometry - Raman spectroscopy - Metrology | - Super-resolution microscopy - DNA sequencing - Medical application (ophthalmology and dermatology) - Laser shows - Petawatt laser line alignment | - Super-resolution microscopy - DNA sequencing - Medical application (ophthalmology and dermatology) - Laser shows - Petawatt laser line alignment |
CEBS: CW Erbium Broadband Source
| KEO-CEBS |
Max Power | 0.1, 0.2, 0.5, 1.0 W |
Wavelength, nm | 1529 - 1562 (BW00) |
Platform | Benchtop |
Output | FC/APC, FC/SPC |
Key Applications | - Optical componenta test - Optical measurement systems - Optical sensing |
If you work with lasers, visit our sections:
- laser power and energy measurement
- laser safety and protection
- laser beam profile analyzers