633nm laser excitation is a common wavelength chosen for Raman spectroscopy as it has a good balance between Raman efficiency, low fluorescence, and affordability.
-Raman-HR-TEC-633 Spectrometers: include an enhanced CCD array detector tuned for 633nm Raman with advanced detector lens assembly for ultra sensitivity at long exposure times.
-Raman-HR-TEC-X2-633 Spectrometers: offer 2-stage detector cooling for ultimate sensitivity and performance! Great for long exposures up to 8 minutes.
Raman Spectrometer | Wavelength Range (cm-1) | Resolution (cm-1) | Integrated 1-Stage TE Cooler | TEC-X2 Option |
---|---|---|---|---|
Raman-HR-TEC-633 | 200-3.900 | 6 | Yes | Yes |
HR = High Resolution
Specifications for StellarNet Raman Configured Spectrometers
Optical Parameters
Optical Resolution: | HR= 6 cm-1 |
Spectral Range: | HR = 200-3.900 cm-1 Early Start Available |
Diffraction Gratings: | 1200 g/mm with gold surface |
Stray Light: | <0.05% |
Optical Input: | SMA-905 |
Detector & Electronics
Detector Type: | SONY ILX CCD 2048 pixels 14um x 200um |
Detector Lens: | Advanced cylindrical lens assembly |
Thermo Electric Cooling: | 1 Stage = -15 Deg C 2 Stage = -30 Deg C |
Exposure Times: | - 20s without TEC - 60s with TEC - 8 minutes with TEC-X2! |
Signal to Noise: | >1000:1 @ Exposure time above 30s TEC 1 has >50% noise reduction and TEC-X2 has >80% |
Physical
Dimensions: | HR/ER= 6 x 17 x 15.5 cm SR = 2.5 x 7.6 x 12.7cm |
Weight: | HR= 1.5 kg SR= 14 ounces |
Software & Interface
Operating System: | Win XP, 7,8,10 Linux |
Interface: | USB-2 (Wifi & Webserver Options) |
Software: | SpectraWiz, SpectraWiz-ID, LabView, Spectroscopy Pro-tools, Delphi, C, C# |
Accessories:
Interchangeable Slits Upgrades: are available for “HR” optical benches to allow more application flexibility. High Scattering samples can be measured with the smallest slit for highest resolution and weak Raman can be measure with a larger slit to allow for increased light throughput.
Raman-Probe-633: Attaches to 830nm laser via FC/APC and spectrometer via SMA 905, has integrated Raman filters and optics (working distance– 4.5mm), high efficiency collection fibers for StellarNet Raman spectrometers
Raman-Probe-TIP: attachements tips can be purchased for additional working distance options. Just screw on to replace
Raman-Probe-TIP-Tele: Telescoping Raman probe tip lens assembly attachment for 3cm working distance. Designed to by mounted on to standard Raman probe with 5mm working distance
RPH4: Raman Probe Holder block supports 1/2″ vials.
RPH5: Vertical Raman Probe Holder Block for powder and solids. Samples are placed onto a slide and inserted into the measurement chamber of the block. Includes a laser safety interlock which only allows the laser to fire when the probe is securely seated into the holder.
Raman-Probe-HT: High Temperature Raman probe to 200 deg C
Raman-Probe-Immersion: Immersion Raman Probes for 633nm source. Stainless-steel, cylindrical probe head with removable immersion sleeve, overall dimensions 5/8″ (15.8mm) diameter x 8″ (230 mm) length
Raman-Probe-Process: Raman Process Probe for 633nm source. Stainless-steel pressure sleeve specified to 3000 psi and up to 500ºC. Sapphire window and gold seal are resistant to many corrosive chemical environments.